ZenTemp+ Operations Guide
Product: ZenTemp+ Function: Rugged wireless temperature and humidity sensor Form Factor: Indoor/outdoor, ruggedized beacon Battery: Replaceable Wireless Protocol: BLE (KSensor, iBeacon, or Eddystone TLM depending on configuration) Typical Range: Environment-dependent (line-of-sight recommended)
Written By Support Team
1. What ZenTemp+ Does
ZenTemp+ is a rugged environmental sensor designed to monitor:
Ambient temperature
Humidity levels
ZenTemp+ advertises sensor data over Bluetooth and requires a compatible BLE gateway (vehicle tracker, camera, or receiver) to forward readings to the platform.
ZenTemp+:
Contains an external button for powering on/off
Non replaceable battery access
Does not provide GPS or motion telemetry
2. Before You Start
You will need:
A ZenTemp+ device
Compatible BLE gateway
Screwdriver
Smartphone with Bluetooth enabled
KBeacon Pro app installed (iOS or Android)
No password is required.
3. Step 1 β Powering On / Off the Device
ZenTemp+ uses an external power button located on the casing.
Power ON / OFF:
Press and hold the internal button to turn the device on or off.
Note: Ensure screws are fully tightened to preserve IP protection and avoid environmental damage. These devices are shipped with the power on
4. Step 2 β Verify Advertising and Sensor Data in KBeacon Pro
Open KBeacon Pro.
Enable Bluetooth on your phone.
Scan for nearby BLE devices.
Locate ZenTemp+ by MAC address or label.
Select the device to view details.
Confirm the following:
Device is visible and advertising
Battery level is adequate
Temperature reading is present and reasonable
Humidity reading is present and reasonable
This ensures the device is functioning before deployment.
5. Step 3 β Add ZenTemp+ to ZenduOne
5.1 Add as a BLE Beacon
Log in to ZenduOne.
Navigate to BLE Beacon or Devices section.
Add a new beacon:
Type: BLE Beacon / Sensor
Enter ZenTemp+ identifier (MAC or serial)
Assign to the correct customer/account
5.2 Link ZenTemp+ to a Gateway / Asset
Open the asset acting as the BLE gateway.
Enable BLE scanning if not already enabled.
Add ZenTemp+ to the BLE configuration (or whitelist).
Save changes.
6. Step 4 β Verify Temperature & Humidity in ZenduOne
Bring ZenTemp+ within BLE range of the gateway.
Open live or asset view in ZenduOne.
Confirm:
Temperature values display correctly
Humidity values display correctly
Refresh as needed based on reporting intervals.
If data does not appear:
Confirm the device is powered on
Check battery level
Verify BLE scanning and whitelisting on the gateway
Ensure the device is assigned to the correct asset